TM 10-3930-633-12
OPERATING
INSTRUCTIONS
If equipment fails to operate, refer to
trouble shooting procedures in Chapter 3.
Section I. OPERATING PROCEDURES
2-1. General
a c c o m p a n y i n g the illustration explains the
This section illustrates and describes the various
function of each control and gives the normal
c o n t r o l s and instruments and provides the
reading for each gage.
operator sufficient information to ensure proper
operation of the tractor.
All controls and instruments for operation of the
Normal Use or Reading
Nomenclature
When turned clockwise to ON, energizes engine ignition, instruments, and accessory
Ignition Switch
circuit. Turning fully clockwise against spring pressure engages engine starter.
Turning counterclockwise to OFF shuts off engine and disconnects gages and ac-
cessory circuits.
Indicates temperature of engine coolant in degrees ( F). Normally 175 F.-200 F. ( 79
Water Temperature Gage
C-93 C)
Indicates engine lubricating oil pressure in PSI. Normally 15-80 PSI (40-60 PSI @ 2000
Oil Pressure Gage
RPM).
Indicates quantity of fuel remaining in fuel tank. E = empty, F = full (tank capacity is 17
Fuel Level Gage
gallons).
Indicates rate of battery charge of discharge. With engine running, should read slightly
to the + side of 440. "
Indicates transmission fluid temperature at converter outlet. DO NOT ALLOW
Transmission Oil Temperature Gage
TEMPERATURE TO EXCEED 250 F. (121 C)
Pull out to illuminate headlights and taillamp. Push in to turn off lights.
Light Switch
Signals when air cleaner element is dirty by displaying read signal. Normally clear.
Air Cleaner Restriction Indicator
Pull out to choke engine for cold starting.
Choke Control
|