TM 9-2320-364-34-1
2-17.1. ARCTIC HEATER (MODEL B) TROUBLESHOOTING (CONT).
12. FAULT CODE 064 OR 065: FLAME SENSOR OPEN CIRCUIT OR
FLAME SENSOR SHORT CIRCUIT.
INITIAL SETUP
References
TM 9-2320-364-10
Tools and Special Tools
TM 9-2320-364-20
Tool Kit, General Mechanic's: Automotive
(Item 241, Appendix F)
Equipment Condition
STE/ICE-R (optional) (Item 15, Appendix F)
Engine OFF, (TM 9-2320-364-10)
Multimeter (Item 140, Appendix F)
Parking brake applied, (TM 9-2320-364-10)
Fault Code Retrieval Device (FCRD)
Wheels chocked, (TM 9-2320-364-10)
(Item 60.1, Appendix F)
NOTE
The following steps should only be used if troubleshooting was started at First Chart
For Diagnosis of Arctic Heater Troubleshooting procedure (Para 2-17.1 Fault 1) (all
conditions) and you were referred here.
START
1.
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING
Continuity test.
on Page 2-766.79
Nothing.
STE/ICE #91.
POSSIBLE PROBLEMS
REASON FOR QUESTION
If resistance reading is be-
Arctic heater flame sensor
Is resistance measured across
tween 900 and 1100 ohms at
faulty.
arctic heater flame sensor be-
room temperature, arctic heater
Arctic heater control unit faulty.
control unit may be faulty. If
tween 900 and 1100 ohms, at
not, arctic heater flame sensor
room temperature?
is faulty.
Replace arctic
heater flame sen-
sor (Para 18-22).
NO
Verify repair, go to
Step 2 of this
Fault.
YES
Replace arctic
heater control unit
(Para 18-2.2).
Verify repair, go to
Step 2 of this
Fault.
2-784