Click here to make tpub.com your Home Page

Page Title: FAULT CODE 050 OR 052: TOO MANY NO START ATTEMPTS OR NO START SAFETY TIME EXCEEDED. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-34-1
8. FAULT CODE 050 OR 052: TOO MANY NO START ATTEMPTS OR NO START
SAFETY TIME EXCEEDED (CONT).
7.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Fuel level OK (checked at
Verify repair.
on Page 2-766.61
operational level).
Arctic heater intake port checks
REASON FOR QUESTION
OK at unit level.
Arctic heater exhaust port and
If arctic heater operates normally,
exhaust tube checks OK at unit
fault has been corrected.
level.
Does arctic heater operate
Arctic heater fuel lines check OK
normally?
at unit level.
Arctic heater fault code 050 not
active.
Arctic heater fuel metering pump
OK.
Arctic heater fuel system primed.
If arctic heater indicator light
Arctic heater flame sensor OK.
flashes or fault code retriev-
Arctic heater glow pin OK.
al device (FCRD) displays
fault code 050, go to Step 8
POSSIBLE PROBLEMS
of this Fault.
If arctic heater indicator light
flashes or fault code retriev-
al device (FCRD) displays
fault code 052, fault not cor-
NO
rected. Notify supervisor.
If arctic heater indicator light
flashes or fault code retriev-
al device (FCRD) displays
fault code other than 050
and 052, troubleshoot fault
YES
code displayed (TM
9-2320-364-20).
Fault corrected.
2-606
82

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business