Click here to make tpub.com your Home Page

Page Title: FAULT CODE 050 OR 052: TOO MANY NO START ATTEMPTS OR NO START SAFETY TIME EXCEEDED. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-34-1
8. FAULT CODE 050 OR 052: TOO MANY NO START ATTEMPTS OR NO START
SAFETY TIME EXCEEDED (CONT).
6.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Fuel level OK (checked at
on Page 2-766.59
operational level).
STE/ICE-R #91.
Arctic heater intake port checks
OK at unit level.
REASON FOR QUESTION
Arctic heater exhaust port and
Is resistance across arctic
exhaust tube checks OK at unit
If resistance reading is not be-
level.
heater flame sensor between
tween 900 and 1100 ohms at
Arctic heater fuel lines check OK
room temperature, arctic heater
900 and 1100 ohms at room
at unit level.
glow pin may be faulty. If not,
temperature?
Arctic heater fault code 050 not
arctic heater flame sensor may
active.
be faulty.
Arctic heater fuel metering pump
OK.
Arctic heater fuel system primed.
Replace arctic heat-
er flame sensor
POSSIBLE PROBLEMS
NO
(Para 18-2.2). Verify
Arctic heater flame sensor faulty.
repair, go to Step 7
Arctic heater glow pin faulty.
of this Fault.
YES
Replace arctic
heater glow pin
(Para 18-2.2).
Verify repair, go to
Step 7 of this
Fault.
2-584
82

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business