TM 9-2320-364-34-1
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits a direct short may result. Damage to equipment, injury or death to personnel may result.
Do not stand under crane. Mechanical failure and operator error can cause injury or death to
personnel.
NOTE
It may be necessary to crack and remove paint
from harness.
VOLTAGE TEST
(1) Loosen two screws on adapter.
(2) Remove adapter and washer from nut.
Slide adapter and washer down
harness and away from nut.
(3) Pull seal from nut while holding
harness to prevent pulling harness out
of connector.
(4) Remove nut from connector.
(5) Set multimeter to volts dc.
(6) Connect positive multimeter lead to
black wire.
(7) Connect negative multimeter lead to
known good ground.
Continued on next page.
|