TM 9-2320-364-34-1
Do not stand under crane. Mechanical failure and operator error can cause injury or death to personnel.
OPERATION TEST
(1) Using HOIST control lever, raise hoist
hook block completely.
(2) Using HOIST control lever, lower hook
block until only one layer of cable
remains on hoist drum.
(a) If test unit does not indicate both
LAYER = ON and LAYER = OFF,
go to Step 9 of this Fault.
(b) If test unit indicates both
LAYER = OFF and LAYER = ON,
adjust hoist proximity sensor
(Para 6-9).
(3) Using HOIST control lever, raise hook
block. Test unit should indicate that
proximity sensor turns on when
third layer of cable starts.
(a) If test unit does not indicate the
proximity sensor is ON, recheck
hoist proximity sensor adjustment
(Para 6-9).
(b) If test unit indicates that proximity
sensor is on, go to Step 12
of this Fault.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |