Do not stand under crane. Mechanical failure and operator error can cause injury or death to personnel.
NOTE
Hoist drum has three layers of cable on it with
hook block raised completely and boom
telescoped out completely.
OPERATION TEST
(1) Raise hoist hook block completely
using HOIST control lever
(TM 9-2320-364-10).
(a) If test unit display indicates
LAYER = OFF, go to Step 8 of
this Fault.
(b) If test unit display indicates
LAYER = ON, go to Step (2)
below.
(2) With the aid of an assistant observing
hoist drum, lower hoist hook block
using HOIST control lever.
(a) If test unit does not indicate
LAYER = OFF the instant the third
layer of cable is off the hoist drum
and only two layers remain, go to
Step 8 of this Fault.
(b) If test unit indicates LAYER = OFF
the instant the third layer of cable
is off the hoist drum and only two
layers remain, hoist proximity
sensor is OK. Go to Step 3 of this
Fault.