TM 9-2320-364-34-1
High pressure hydraulics [oil under 3000 psi (20,685 kPa) pressure] operate this equipment. Refer to
vehicle operator and maintenance manuals for hydraulic oil pressure. Never disconnect any hydraulic
line or fitting without first dropping pressure to zero. Failure to comply may result in injury to personnel.
Fuel and oil are slippery and can cause falls. To avoid injury, wipe up spilled fuel or oil with rags.
NOTE
Use a drain pan to catch leaking hydraulic oil.
VISUAL INSPECTION
(1) Remove four valve bank from
crane (Para 16-26).
(2) Remove HOIST valve from
four valve bank (Para 16-26).
(3) Remove orifice from four valve bank
where HOIST valve was
removed from (Para 16-26).
(4) Inspect orifice for contamination
clogging it.
(a) If orifice is contaminated, clean
or replace orifice and inspect
bores in HOIST valve for
additional contaminants
(Para 16-26).
(b) If orifice is OK, repair HOIST
valve on four valve bank
(Para 16-26).
(5) Install orifice on four valve
bank (Para 16-26).
(6) Install HOIST valve on four
valve bank (Para 16-26).
(7) Install four valve bank on crane
(Para 16-26).
(8) Install cover with four screws,
washers, lockwashers, and nuts.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |