TM 9-2320-364-34-1
High pressure hydraulics [oil under 3000 psi (20,685 kPa) pressure] operate this equipment. Refer to
S
vehicle operator and maintenance manuals for hydraulic oil pressure. Never disconnect any hydraulic
line or fitting without first dropping pressure to zero. Failure to comply may result in injury to personnel.
Fuel and oil are slippery and can cause falls. To avoid injury, wipe up spilled fuel or oil with rags.
S
NOTE
Use a drain pan to catch leaking hydraulic oil.
FLOWMETER TEST
(1) Tag, mark and disconnect hose
from fitting at bottom of MAST
valve. Discard preformed packing.
(2) Connect adapter hose with
preformed packing to disconnected
hose.
(3) Connect adapter hose to flowmeter
IN port.
(4) Connect adapter hose with
preformed packing to fitting.
(5) Connect adapter hose to flowmeter
OUT port.
(6) Open flowmeter load valve.
(7) Start engine (TM 9-2320-364-10).
(8) Set WINCH/CRANE switch to
CRANE position.
(9) Set hydraulic selector switch to
CRANE/SRW position.
(10) Turn ON crane POWER
switch.
(11) Hold MAST control lever in DOWN
position while observing flowmeter.
(a) If more than 0 gpm (0 lpm)
are present, perform Steps (12)
through (17) below and replace
erection cylinder (Para 16-5).
(b) If 0 gpm (0 lpm) are present,
cylinder piston seals are OK.
Fault not corrected. Perform
Steps (12) through (17) below
and notify supervisor.
(12) Set crane POWER switch to
OFF position.
(13) Set hydraulic selector switch to OFF
position.
(14) Turn OFF ENGINE switch.
(15) Disconnect adapter hose from crane
hose. Discard preformed packing.
(16) Disconnect adapter hose from
fitting. Discard preformed packing.
(17) Connect crane hose with preformed
packing to fitting.
|