TM 9-2320-364-34-1
11. LHS HOOK ARM DISENGAGES FROM FLATRACK WHILE UNLOADING (CONT).
2.
TEST OPTIONS
KNOWN INFO
Clearance measurement test.
Flatrack hook bar wear OK.
Is clearance between LHS
hook arm and flatrack hook
REASON FOR QUESTION
POSSIBLE PROBLEMS
bar greater than 0.875 in. (22.2
If the LHS hook arm or flatrack
mm)?
Flatrack hook bar height out of
hook bar height is out of
tolerance.
tolerance, the hook arm could
LHS hook arm out of tolerance.
slide under the flatrack hook bar
when attempting to unload the
flatrack.
Fault not corrected.
NO
Notify supervisor.
YES
Go to Step 3 of this
Fault.
2-412
|