2-14. LOAD HANDLING SYSTEM (LHS) TROUBLESHOOTING (CONT).
11. LHS HOOK ARM DISENGAGES FROM FLATRACK WHILE UNLOADING.
INITIAL SETUP
References
Tools and Special Tools
TM 9-2320-364-10
Gage Set, Telescoping (Item 69, Appendix F)
TM 9-3990-206-14&P
Level (Item 134, Appendix F)
Micrometer, Outside, Caliper, Set
Equipment Condition
(Item 139, Appendix F)
Flatrack unloaded, (TM 9-2320-364-10)
Plumb Bob (Item 161, Appendix F)
Ruler, Tape (Item 235, Appendix F)
Wooden Block (4) (Appendix C)
Personnel Required
Two
START
1.
KNOWN INFO
TEST OPTIONS
Nothing.
Wear measurement test.
Is flatrack hook bar wear
within tolerance?
POSSIBLE PROBLEMS
REASON FOR QUESTION
Excessive wear on flatrack hook
Excess flatrack bar wear could
bar.
cause LHS hook arm to slide
Flatrack hook bar height out of
under hook bar when attempting
tolerance.
to unload the flatrack.
LHS hook arm out of tolerance.
Repair flatrack.
NO
Verify repair, go to
Step 4 of this Fault.
YES
Go to Step 2 of this
Fault.