TM 9-2320-364-34-1
10. LOSS OF MIDDLE FRAME LOAD HOLDING (CONT).
3.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Unit Troubleshooting tasks
Flowmeter test.
on Page 2-395
completed.
LHS operates.
REASON FOR QUESTION
Main cylinder manifold relief
Are 0 gpm measured at LH
valve OK.
If fluid flow is getting past LH
main manifold, port VA with
main cylinder piston seals,
POSSIBLE PROBLEMS
middle frame will not hold load.
LHS in transit position while
holding joystick in LOAD
LH main cylinder faulty.
position?
RH main cylinder faulty.
Load control valve faulty.
Replace LH main
cylinder (Para 17-15).
NO
Verify repair, go to
Step 5 of this Fault.
YES
2-394
|