Click here to make tpub.com your Home Page

Page Title: MIDDLE FRAME DOES NOT UNLOAD. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-34-1
The LHS hydraulic system operates at oil
S
pressures up to 3675 psi (25,339 kPa).
Never disconnect any hydraulic line or
fitting without first dropping pressure
to zero. Failure to comply may result in
serious injury or death to personnel.
Fuel and oil are slippery and can cause
S
falls. To avoid injury, wipe up spilled
fuel or oil with rags.
FLOWMETER TEST
(1) Disconnect hose 2917 male quick
disconnect from LHS control box
female quick disconnect.
(2) Disconnect hose 2666 from RH
main cylinder manifold adapter
port VB.
(3) Connect adapter hose to hose 2666.
(4) Connect adapter hose to main
cylinder manifold adapter port VB.
(5) Connect flowmeter OUT port to
adapter hose connected to
hose 2666.
(6) Connect flowmeter IN port to
adapter hose connected to
RH main cylinder manifold.
(7) Completely open flowmeter load
valve.
(8) Set flowmeter to LOW scale.
(9) Connect quick disconnect
hose 2917.
(10) Start engine (TM 9-2320-364-10).
(11) Set hydraulic selector switch
to MAN MF position.
(12) With the aid of an assistant, observe
flowmeter while holding joystick in
UNLOAD position.
(a)  If more than 0 gpm (0 lpm) are
present, perform Steps (13)
through (21) below and replace
RH main cylinder (Para 17-15).
(b)  If 0 gpm (0 lpm) are present,
RH main cylinder is OK.
(13) Put LHS in transit position.
(14) Set hydraulic selector switch to OFF
position.
(15) Turn OFF ENGINE switch.
(16) Disconnect hose 2917 male quick
disconnect from LHS control box
female quick disconnect.
(17) Disconnect flowmeter from two
adapter hoses.
(18) Disconnect adapter hose main
cylinder manifold adapter.
(19) Disconnect adapter hose from
hose 2666.
(20) Connect hose 2666 to main
cylinder manifold adapter port VB.
(21) Connect quick disconnect
hose 2917.

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business