The LHS hydraulic system operates at oil pressures up to 3675 psi (25,339 kPa). Never disconnect any
S
hydraulic line or fitting without first dropping pressure to zero. Failure to comply may result in serious
injury or death to personnel.
Fuel and oil are slippery and can cause falls.
S
To avoid injury, wipe up spilled fuel or oil
with rags.
PRESSURE TEST (CONT).
(14) Turn OFF ENGINE switch.
(15) Disconnect hose 2917 male quick
disconnect from LHS control box
female quick disconnect.
(16) Remove pressure gage from main
manifold.
(17) Lubricate preformed packing and
backup ring with hydraulic oil.
(18) Install preformed packing and
backup ring on plug and install
plug in main manifold, port TPMB.
Tighten to 96 lb-in (11 N.m).
(19) Remove caps and plugs from six
bulkhead fittings and hoses.
(20) Connect six hoses to bulkhead
fittings.
(21) Connect quick disconnect
hose 2917.