TM 9-2320-364-34-1
7. MIDDLE FRAME DOES NOT UNLOAD (CONT).
The LHS hydraulic system operates at oil
S
pressures up to 3675 psi (25,339 kPa).
Never disconnect any hydraulic line or
fitting without first dropping pressure
to zero. Failure to comply may result in
serious injury or death to personnel.
Fuel and oil are slippery and can cause
S
falls. To avoid injury, wipe up spilled
fuel or oil with rags.
PRESSURE TEST (CONT).
(11) With the aid of an assistant, observe
pressure gage while holding
joystick in UNLOAD position.
(a) If less than 3600 psi
(24,822 kPa) is present,
perform Steps (12) through
(21) below and replace RH
(inboard) load control valve
(Para 17-6).
(b) If 3600 psi (24,822 kPa) or more
are present, load control valve
is OK.
(12) Put LHS in transit position.
(13) Set hydraulic selector switch to OFF
position.
Continued on next page.