FLOWMETER TEST
(1) Disconnect hose 2917 male quick
disconnect from LHS control box
female quick disconnect.
(2) Disconnect hose 2887 from RH
main manifold adapter port VA.
(3) Connect adapter hose to hose 2887.
(4) Connect adapter hose to main
cylinder manifold adapter port VA.
(5) Connect flowmeter OUT port to
adapter hose connected to
hose 2887.
(6) Connect flowmeter IN port to
adapter hose connected to
manifold.
(7) Completely open flowmeter
load valve.
(8) Set flowmeter to LOW scale.
(9) Connect quick disconnect
hose 2917.
(10) Start engine (TM 9-2320-364-10).
(11) Set hydraulic selector switch to
MAN MF position.
(12) With the aid of an assistant, observe
flow meter while holding joystick in
LOAD position.
(a) If more than 0 gpm (0 lpm) are
present, perform Steps (13)
through (23) below and replace
RH main cylinder (Para 17-15).
(b) If 0 gpm (0 lpm) are present,
RH main cylinder is OK.
(13) Set hydraulic selector switch to OFF
position.
(14) Turn OFF ENGINE switch.
(15) Disconnect hose 2917 male quick
disconnect from LHS control box
female quick disconnect.
(16) Disconnect flowmeter from two
adapter hoses.
(17) Disconnect adapter hose main
cylinder manifold adapter.
(18) Disconnect adapter hose from
hose 2887.
(19) Connect hose 2887 to main cylinder
manifold adapter port VA.
(20) Connect quick disconnect
hose 2917.
|