6. MIDDLE FRAME DOES NOT LOAD (CONT).
5.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Unit Troubleshooting tasks
Pressure test.
on Page 2-333
completed.
Middle frame unloads.
REASON FOR QUESTION
Middle frame down directional
Are less than 1300 psi
If load control valve is faulty,
control valve OK.
return flow from main cylinders
(8964 kPa) measured at main
Load control valve OK.
will be restricted causing
Main cylinder manifold
manifold, port TPMA when
excessive pressure.
relief valves OK.
attempting to load?
POSSIBLE PROBLEMS
Load control valve faulty.
LH main cylinder faulty.
Replace RH (inboard)
RH main cylinder faulty.
main cylinder
manifold load control
NO
valve (Para 17-6).
Verify repair, go to
Step 8 of this Fault.