Click here to make tpub.com your Home Page

Page Title: FAN SPEED DOES NOT DECREASE FROM HIGH TO LOW SPEED. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-34-1
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
Table 2-13. EPAC Temperature vs Voltage
Values
Voltage
Water Temp. Gage
Reading
Values
F
C
(vdc)
170
77
22
175
79
16
185
85
12
190
88
10
202-204
94-96
7.3-7.7
VOLTAGE TEST
(1)
Remove 22 screws, lockwashers,
washer and access panel. Discard
lockwashers.
(2)  Set multimeter select switch to
volts dc.
(3)  Start engine (TM 9-2320-364-10).
(4)  Allow engine to warm up to at least
175F (79C) and turn OFF
ENGINE switch.
(5)  Disconnect connector MC76 from
fan control solenoid valve.
(6)  Connect positive (+) multimeter
lead to wire 1936 at harness
connector MC76, terminal A.
(7)  Connect negative (- ) multimeter
-
lead to wire 1935 at harness
connector MC76, terminal B.
(8)  While assistant turns ON ENGINE
switch, observe multimeter and
check EPAC output voltages versus
engine water temperature readings
(a) If voltage outputs are not
correct, perform Steps (9)
through (11) below and adjust or
replace EPAC (Para 6-12).
(b) If voltage outputs are correct,
replace fan control solenoid
valve (TM 9-2320-364-20).
(9)  Turn OFF ENGINE switch.
(10) Connect connector MC76 to fan
control solenoid valve connector.
(11)  Install inside access panel with 22
washers, lockwashers and screws.

Privacy Statement - Press Release - Copyright Information. - Contact Us