Page Title: FAN DOES NOT OPERATE. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-34-1
High pressure hydraulics [oil under 3675 psi
(25,339 kPa) pressure] operate this
equipment. Refer to vehicle operator and
maintenance manuals for hydraulic oil
pressure. Never disconnect any hydraulic line
or fitting without first dropping pressure to
zero. Failure to comply may result in injury to
personnel.
Fuel and oil are slippery and can cause falls.
To avoid injury, wipe up spilled fuel or oil
with rags.
NOTE
Use drain pan to catch leaking hydraulic oil.
Only remove center screw on engine side of
LHS control box cover.
VISUAL/AUDIBLE INSPECTION
(1) Remove eight screws, lockwashers,
washers and left side noise
panel. Discard lockwashers.
(2) Remove four screws, lockwashers and
LHS control box cover. Discard
lockwashers.
(3) Remove shuttle valve B from
multifunction manifold.
(4) Remove and discard three preformed
packings and two packing retainers.
(5) Shake valve and listen for ball to
rattle.
(a) If ball does not rattle, clean or
replace shuttle valve B
(Para 17-18).
(b) If check ball rattles, shuttle valve
is OK.
(6) Lubricate two preformed packings
and packing retainers with hydraulic
oil and install on shuttle valve.
(7) Install shuttle valve B.