2-13. HYDRAULIC SYSTEM TROUBLESHOOTING (CONT).
2. FAN, LHS, WINCH AND CRANE DO NOT OPERATE OR OPERATE SLOWLY.
INITIAL SETUP
Tools and Special Tools
References
Tool Kit, General Mechanic's
TM 9-2320-364-10
(Item 240, Appendix F)
TM 9-2320-364-20
Pan, Drain 4 gal (Item 144, Appendix F)
Pressure Test Kit (Item 165, Appendix F)
Equipment Condition
Engine OFF, (TM 9-2320-364-10)
Materials/Parts
Parking brake applied, (TM 9-2320-364-10)
Oil, Hydraulic (Item 34, Appendix B)
Wheels chocked, (TM 9-2320-364-10)
START
1.
KNOWN INFO
TEST OPTIONS
Does pump make excessive
Unit Troubleshooting
Audible inspection.
noise when operating?
tasks completed.
REASON FOR QUESTION
POSSIBLE PROBLEMS
If main hydraulic pump makes
excessive noise during
Main hydraulic pump faulty.
operation, internal components
Hydraulic pump control faulty.
are faulty and pump will not
supply fluid for correct hydraulic
system operation.
Go to Step 2 of this
NO
Fault.
YES
Replace hydraulic
pump (Para 17-2).
Verify repair, go to
Step 3 of this Fault.