TM 9-2320-364-34-1
1. AIR PRESSURE BUILDUP IS SLOW (CONT).
3.
TEST OPTIONS
KNOWN INFO
Verify repair.
Unit Troubleshooting tasks
Does air pressure still build
completed.
up slowly?
REASON FOR QUESTION
Compressor cylinder head
gasket OK.
If pressure builds up in
Air compressor OK.
five minutes or less, fault has
been corrected.
POSSIBLE PROBLEMS
Fault corrected.
NO
YES
Fault not corrected,
notify supervisor.
2-182
|