TM 9-2320-364-34-1
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
Blowing transmission oil can cause injury to eyes. Safety goggles must be worn when testing
transmission oil pressure switch.
CONTINUITY TEST
(1) Remove two screws, forward pressure
switch and preformed packing.
Discard preformed packing.
(2) Disconnect pressure switch
connector.
(3) With the aid of an assistant, apply
25 to 35 psi (172 to 241 kPa) air to
pressure switch orifice and check
continuity across pressure switch.
(a) If there is no continuity, replace
forward pressure switch
(Para 7-8).
(b) If there is continuity, pressure
switch is OK.
(4) Install preformed packing, pressure
switch and two screws. Tighten
screws to 60 to 84 lbs-in
(6.8 to 9.5 N.m).
|