Section IV. TROUBLESHOOTING CHARTS (Cont.)
D. CHART - 6 - "CHECK GAUGES" LIGHT ON AND NO ACTIVE CODE ON DDR (Cont'd)
-
STEP/SEQUENCE
RESULT
WHAT TO DO NEXT
C 6-30
Verify Repairs
Turn ignition off.
"Check Gauges"
Repairs are complete.
Reconnect all connectors.
light comes on for
Turn ignition on.
up to 5 seconds
Clear codes.
then goes out.
Turn ignition off.
Turn ignition on while at same
"Check Gauges"
All system diagnostics are
time observing "Check Gauges"
light comes on
complete. Please review this
light.
and stays on.
section from the first step to find
error.