TM 9-2320-364-20-1
Section IV. TROUBLESHOOTING CHARTS (Cont.)
C. START - FIRST CHART FOR DIAGNOSIS OF DDEC III/IV USING DDR (Cont'd)
STEP/SEQUENCE
RESULT
WHAT TO DO NEXT
START-8
Check for Short
Plug DDR into Connector.
Select SWITCH/LIGHT STATS
on DDR.
Read Diagnostic Request SW.
ON.
Ckt #528 is shorted
status.
to ground. Repair short,
then go to START-30.
OFF.
Go to Chart 9, page 2-605.
START-9
Check for +12
Volts at DDR
Connector
Turn ignition on.
Greater than
There is a problem with either
Read voltage at the DDR
or equal to 10.0 volts.
the DDR or the data link lines.
connector, from pin "H" (red lead)
Go to C 7-4, page 2-595. (For
to pin "A" (black lead).
diagnosis of DDEC III/IV without a
DDR, go to CEL-1 on page
Less than
Either the switched +12 volt line
10.0 volts.
or the ground line is open to the
DDR connector. Repair open.
Then go to START-30.