C. START - FIRST CHART FOR DIAGNOSIS OF DDEC III/IV USING DDR (Cont'd)
STEP/SEQUENCE
RESULT
WHAT TO DO NEXT
START-3
Read All Codes
Using DDR
Plug DDR into DDL
Codes 52, 110, 175/3,
Follow appropriate diagnostic
connector.
174/3, or 190/0.
charts for code(s) received.
Read all inactive codes by
Any codes except
Go to START-4.
selecting inactive codes
52, 110, 175/3,
on DDR.
174/3, or 190/0.
No Codes.
Go to Chart 1, page 2-554.
DDR display reads
Go to Chart 7, page 2-593.
"NO DATA
RECEIVED FROM
SYSTEM" or "DDEC
SYSTEM NOT
RESPONDING".
DDR display is
Go to START-9.
blank or random.
START-4
Attempt to Make
Codes Active
*SEE NOTE BELOW*
Clear codes by selecting
Engine will
Go to Chart 2, page 2-557.
CLEAR CODES on the DDR.
not start.
Attempt to start and run
the engine (TM 9-2320-364-10).
Try to get the "Check Engine" light
"Check Engine"
Read active codes on DDR
on by:
light is on.
while light is on and follow
-- warming up the engine.
the appropriate diagnostic
-- slowly changing the RPM from
chart in Table 2-19.
idle to no load speed.
If truck is equipped with crane,
push ENGINE HIGH IDLE LATCH
switch to LATCH and release.
Run engine for 1 minute or until
"Check Engine"
Problem may be intermittent --
"Check Engine" light comes on.
light is off.
See Chart 1, page 2-554, Step
C 1-2.
"Check Engine"
Go to START-5.
flashes briefly.
*NOTE:
If a potential engine damaging Code (i.e., 100/1) exists, monitor that parameter