2-14. DDEC III/IV TROUBLESHOOTING (CONT).
Section IV. TROUBLESHOOTING CHARTS (Cont.)
FLASH CODE:
71
DDR DISPLAY:
XXX INJECTOR RESPONSE TIME SHORT
SAE J1587 CODE:
SID: XX FMI: 1
Indicates that the time it takes from when the DDEC III/IV ECM requests an injector be turned on to when the in-
jector solenoid valve actually closes is shorter than the lower limit of the expected range. This diagnostic condi-
tion is typically:
(1)
aerated fuel system
(2)
high system battery (+) supply voltage
(3)
failed solenoid valve
NOTE: The injector diagnostic SID (Subsystem IDentifier) indicates which cylinder number has an injector with a
short response time. The injector number describes the cylinder and/or bank which has the injector with
a short response time.
Injector response times generally increase with low battery supply voltage and decrease with high battery
supply voltage. Although injector response times vary from injector to injector at a given RPM, each indi-
vidual injector response time should remain relatively consistent from one firing to the next. Wide varia-
tions in response time (typically +/-- 0.2 msec) for one injector at a steady engine RPM may indicate an
electrical problem (faulty alternator or voltage regulator, poor or broken ground cables, etc.).
FLASH CODE:
75
DDR DISPLAY:
ECM BATTERY VOLTAGE HIGH
SAE J1587 CODE:
PID: 168 FMI: 0
Indicates that the DDEC III/IV ECM has detected that the main battery supply voltage to the ECM has exceeded
the recommended operating range.
FLASH CODE:
76
DDR DISPLAY:
ENGINE OVERSPEED WITH ENGINE BRAKE
SAE J1587 CODE:
PID: 121 FMI: 0
Indicates that the engine RPM has exceeded the recommended safe operating range.
FLASH CODE:
85
DDR DISPLAY:
ENGINE OVERSPEED
SAE J1587 CODE:
PID: 190 FMI: 0
Indicates that the engine RPM has exceeded the recommended safe operating range.
FLASH CODE:
-- --
DDR DISPLAY:
FRAM CHECKSUM INCORRECT
SAE J1587 CODE:
SID: 240 FMI: 2
Indicates that the ECM system operation software has been corrupted and is unable to operate. This diagnostic
condition is typically:
The ECM system programming operation failed to run to completion. Replace ECM (para 7-57).
FLASH CODE:
-- --
DDR DISPLAY:
INCOMPATIBLE CALIBRATION VERSION
SAE J1587 CODE:
SID: 253 FMI: 13
Indicates that the current ECM system operation software is not compatible with the engine calibration loaded in
the ECM. This diagnostic condition is typically:
The ECM programming process was performed in the incorrect order or did not run to completion. Replace ECM
(para 7-57).
2-534
|