Click here to make tpub.com your Home Page

Page Title: CODE 36 OIL PRESSURE SENSOR (OPS) SIGNAL VOLTAGE LOW (CONT).
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-20-1
A4 CODE 36 OIL PRESSURE SENSOR (OPS) SIGNAL VOLTAGE LOW (CONT).
3.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
CHECK ENGINE light (CEL)
Visual inspection.
comes ON and stays ON.
REASON FOR QUESTION
POSSIBLE PROBLEMS
Are OPS terminals and
Damage to terminals or
OPS connector faulty.
connectors free from
connectors can affect signal to
OPS faulty.
OPS.
damage?
Wire 530 is open.
Wires 530 and/or 452 are
shorted.
DDEC ECM harness connector
faulty.
Wires 416 and/or 452 are open.
Wires 416 and/or 452 are
Repair OPS
shorted.
connectors
Wires 530, 439, 241 and/or 240
NO
(Para 7-101).
are shorted.
Verify repair, go to
Step 12 of this Fault.
YES
Replace OPS
(Para 7-67).
Verify repair, go to
Step 12 of this Fault.
4.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
CHECK ENGINE light (CEL)
Voltage test.
comes ON and stays ON.
STE/ICE-R #89.
OPS connector OK.
OPS OK.
REASON FOR QUESTION
Is there 4 to 6 vdc measured
POSSIBLE PROBLEMS
from wire 416 to 452 at OPS
Incorrect voltage possible.
harness connector, terminals
Wire 530 is open.
C to A?
Wires 530 and/or 452 are
shorted.
DDEC ECM harness connector
faulty.
Wires 416 and/or 452 are open.
If less than 4 volts, go
Wires 416 and/or 452 are
to Step 8 of this Fault.
shorted.
NO
If more than 6 volts,
Wires 530, 439, 241 and/or 240
go to Step 10 of this
are shorted.
Fault.
YES