TM 9-2320-364-20-1
NOTE
The following steps should only be
used if troubleshooting was started
at DDEC II Troubleshooting (All Conditions)
and you were referred here.
DDR TEST
(1) Connect DDR to DDL
connector MC13.
(2) Turn ON ENGINE switch
(TM 9-2320-364-10).
(3) Select MODE 01 (ACTIVE CODES)
on DDR.
(a) If Code 15 is not the only code
and Codes 14, 23, 24 or 33
appear, turn OFF ENGINE switch
and go to Fault A5B (Table 2-16).
(b) If Code 15 or any other codes
except 14, 23, 24 or 33 appear,
turn OFF ENGINE switch and go
to Step 2 of this Fault.
2-211