A4 CODE 12 VERNIER CONTROL SIGNAL VOLTAGE HIGH (CONT).
8.
KNOWN INFO
TEST OPTIONS
CHECK ENGINE light (CEL)
Verify repair.
comes ON and stays ON.
Does CEL stay ON longer
Code 12 only displayed on
than five seconds?
REASON FOR QUESTION
DDR.
Wire 952 OK.
If CEL lights for approximately
Vernier control connector OK.
five seconds and then goes
Vernier control OK.
OUT after ENGINE switch is
Wires 1525 and/or 510 not
turned to ON, Fault has been
shorted.
corrected.
Wire 952 not shorted.
DDL connector and/or vehicle
harness connector MC18 OK.
DDEC ECM OK.
POSSIBLE PROBLEMS
Fault corrected.
NO
YES
Go to Fault Index