NOTE
The following steps should only be used if
Troubleshooting was started at DDEC II
Troubleshooting (All Conditions) and you were
referred here.
DDR TEST
(1) Connect DDR to DDL connector
MC13.
(2) Turn ON ENGINE switch
(TM 9-2320-364-10).
(3) Select MODE 01 (ACTIVE CODES)
on DDR.
(a) If there are more than Code 12 on
DDR display, turn OFF ENGINE
switch and go to Fault A5A
(b) If there are not more codes than
Code 12, turn OFF ENGINE
switch and go to Step 2 of this
Fault.