Click here to make tpub.com your Home Page

Page Title: Table 2-1. Unit Level Preventive Maintenance Checks and Services (PMCS) (CONT).
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-20-1
Table 2-1. Unit Level Preventive Maintenance Checks and Services (PMCS) (CONT).
Interval
Item to Be
Procedure
Not Mission
Item
Inspected
Capable If:
No.
NOTE
Prior to checking fluid level, ensure the
LHS and crane (if installed) are in the
stowed position to obtain an accurate fluid
level reading.
OE/HDO-30 must be used when
temperatures are consistently above 60
degrees F (16 degrees C).
When oil is cold, do not add or fill beyond
the word "FULL" on the fluid level
indicator.
118
Annual
Main
a. Drain main hydraulic reservoir every 800
a. Any Class III leaks
Hydraulic
hours of operation or annually, whichever
are found.
Reservoir
comes first. Refer to Para 20-11. Refill with
OE/HDO as required. Refer to Table 2-3.
b. Replace strainers in the main hydraulic
reservoir every 800 hours of operation or
annually, whichever comes first. Refer to Para
20-13.
2-77

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business