TM 9-2320-364-20-1
Table 2-1. Unit Level Preventive Maintenance Checks and Services (PMCS) (CONT).
Interval
Item to Be
Procedure
Not Mission
Item
Inspected
Capable If:
No.
NOTE
Prior to checking fluid level, ensure the
LHS and crane (if installed) are in the
stowed position to obtain an accurate fluid
level reading.
OE/HDO-30 must be used when
temperatures are consistently above 60
degrees F (16 degrees C).
When oil is cold, do not add or fill beyond
the word "FULL" on the fluid level
indicator.
118
Annual
Main
a. Drain main hydraulic reservoir every 800
a. Any Class III leaks
Hydraulic
hours of operation or annually, whichever
are found.
Reservoir
comes first. Refer to Para 20-11. Refill with
OE/HDO as required. Refer to Table 2-3.
b. Replace strainers in the main hydraulic
reservoir every 800 hours of operation or
annually, whichever comes first. Refer to Para
20-13.