Table 2-1. Unit Level Preventive Maintenance Checks and Services (PMCS) (CONT).
Interval
Item to Be
Procedure
Not Mission
Item
Inspected
Capable If:
No.
DRAIN PLUG
(OLD STYLE OIL PAN)
DRAIN PLUG
(NEW STYLE OIL PAN)
NOTE
When initially filling or changing the
transmission fluid, use the COLD band on
dipstick. At an initial operating temperature
of 60 to 120 degrees F (16 to 49 degrees C)
fill the transmission so the fluid is in COLD
range.
Loosen T-handle on transmission dipstick
approximately one full turn then dipstick
can be removed from check and fill tube
with slight resistance.
Operate engine one minute at 1000 RPM,
idle until transmission temperature reaches
180 to 220 degrees F (82 to 104 degrees C).
With engine idling, transmission in neutral,
and truck on level ground, check
transmission dipstick. If oil level is within
the HOT/RUN band the quantity of oil in
the transmission is safe for operation. If oil
level is on or below bottom line of
HOT/RUN band, add oil.
115
Annual
Transmission
Drain fluid from transmission and service
Any Class III leaks are
Fluid and
transmission breather every 6,000 miles (9,656
found.
Breather
km) or annually, whichever comes first. Refer
to Para 8-3 and Para 8-5. Refill with OE/HDO
as required. Refer to Table 2-3.
2-75