Table 2-1. Unit Level Preventive Maintenance Checks and Services (PMCS) (CONT).
Interval
Item to Be
Procedure
Not Mission
Item
Inspected
Capable If:
No.
96
Semi-
Material
a. Raise crane boom (1) and extend stages
a. Piston rods are
Annual
Handling
(2) (TM 9-2320-364-10). Check cylinder
scored or bent.
Crane
piston rods (3) for bends and scoring.
b. Check crane boom (1) for deformation,
b. Crane boom is
cracks or broken welds.
deformed, cracked or
has broken welds.
97
Semi-
Boom
Inspect boom chain/cable adjustment. Retract
Clearance is more than
Annual
Chain/Cable
boom and manually push in end of boom
1/32 in. (0.79 mm).
Adjustment
completely back to stops. Pull out on adjusting
nut (1) and check for clearance between
washer (2) and stop plate (3).