TM 9-2320-364-20-1
2-9. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
TABLES (CONT).
Table 2-1. Unit Level Preventive Maintenance Checks and Services (PMCS) (CONT).
Interval
Item to Be
Procedure
Not Mission
Item
Inspected
Capable If:
No.
76
Semi-
Hydraulic
a. Inspect universal joints (1) for looseness.
a. Movement of
Annual
Pump
universal joints.
Driveshaft
b. Inspect slip yoke (2) for looseness.
b. Movement of
slip yoke.
NOTE
If an air-operated grease gun does not purge
the fitting, use a hand-operated grease gun.
If the part does not purge, remove fitting
and clean, install fitting and grease again. If
part still does not purge, refer to
maintenance task for that component.
When using a grease gun, apply lubricant to
the fitting until clean lubricant squeezes out
of the part being lubricated.
c. Lubricate the hydraulic pump driveshaft
c. Fittings will not
with GAA every 3,000 miles (4,828 km)
purge old lubricant
or semiannually, whichever comes first.
of component.
77
Semi-
Transmission
Check transmission for cracks, leaks or
Obvious cracks, damage
Annual
obvious damage.
or leaks are found.