Table 2-1. Unit Level Preventive Maintenance Checks and Services (PMCS) (CONT).
Interval
Item to Be
Procedure
Not Mission
Item
Inspected
Capable If:
No.
NOTE
Self-recovery winch (SRW) has two plugs. To
check and fill SRW, one plug must be in upper
position and second plug must be at side
position. To drain SRW, one plug must be in
side position and one plug must be at bottom
position.
58
Semi-
Self-
a. Check fluid level in SRW gearbox every
a. Any Class III leaks
Annual
Recovery
6,000 miles (9,656 km) or semiannually,
are found.
Winch
whichever comes first. Fill with GO as
required. Refer to Table 2-3.
b. Check torque of SRW mounting screws
b. Mounting screws
(1). Tighten SRW mounting screws to 210
are loose, broken or
lb-ft (285 N.m). Replace mounting screws if
missing.
broken or missing. Refer to Para 18-12.
2-47