TM 9-2320-363-20-2
AIR CONDITIONER BINARY SWITCH REPLACEMENT
This task covers:
a Removal
b. Installation
INITIAL SETUP
Applicable Configuration:
General Safety Instructions:
All except M915A2 and M916A1
WARNING
Use care to prevent refrigerant from
Tools and Special Equipment:
touching your skin or eyes, because
Tool Kit, SC 5180-90-CL-N26
liquid refrigerant, when exposed to air,
quickly evaporates and will freeze skin or
Materials/Parts:
eye tissue. Serious injury or blindness
could result if you come in contact with
Packing, Preformed
P/N 2-011C944-70
liquid refrigerant.
Loctite
Appendix B, Item 33
Refrigerant R-134a air conditioning
Oil, Refrigerant
Appendix B, Item 67
system should not be pressure tested or
Equipment Condition:
leak tested with compressed air.
Combustible mixtures of air and R-134a
Reference
Condition Description
may form, resulting in a fire or explosion,
which could cause personal injury
Page 2-29
Batteries Disconnected
References:
TM 9-2320-363-10
REMOVAL
1.
DISCONNECT HARNESS CONNECTOR (1) FROM BINARY SWITCH (2)
2.
REMOVE THE BINARY SWITCH (2) FROM RECEIVER-DRIER (3).
INSTALLATION
1.
LUBRICATE NEW O-RING WITH REFRIGERANT
OIL, THEN INSTALL OVER MALE THREADS OF
RECEIVER-DRIER COUPLING.
2.
INSTALL BINARY SWITCH (2) AND TIGHTEN
TO 20 TO 25 LB-FT (27 TO 34 N.m).
3.
CONNECT HARNESS CONNECTOR (1).
NOTE
Follow-on Maintenance:
Connect batteries (page 2-29).
Operate air conditioner system (TM 9-2320-363-10).