![]() TM 9-2320-363-20-2 
AIR DRYER REPLACEMENT 
This task covers: a. Removal b. Cleaning/Inspection c. Installation 
INITIAL SETUP 
Applicable Configuration: 
General Safety Instructions: 
) 
M916A1 and M916A2 
WARNING 
 Make sure all air lines and 
Tools and Special Equipment: 
fittings are clear of debris. 
Tool Kit, SC 5180-90-CL-N26 
Make sure excess pipe 
sealant compound does not 
Materials/Parts: 
enter air lines or fittings. 
Failure to do so could result 
Nut, Lock (4) 
in equipment failure and/or 
injury to personnel. 
Nut, Lock (4) 
 Sealant compounds can burn 
Compound, Pipe 
Appendix C, Item 8 
easily, can give off harmful 
Sealing 
vapors, and are harmful to 
skin and clothing. To avoid 
Equipment Condition: 
injury or death, keep away 
fromopen fi re and use in 
Reference 
Condition Description 
well-ventilated area. If sealant 
compound gets on skin or 
Page 2-28 
Air System Drained 
clothing, wash immediately 
with soap and water. 
REMOVAL 