REAR QUICK-RELEASE VALVE REPLACEMENT
This task covers:
a. Removal b. CleaninG/lnspection c. Installation
INITIAL SETUP
General Safety Instructions:
Tools and Special Equipment:
Tool Kit, SC 5180-90-CL-N26
WARNING
Materials/Parts:
M a k e sure all air lines and
fittings are clear of debris.
Nut, Lock (2)
Make sure excess pipe
Appendix C, Item 8
Compound, Pipe
sealant compound does not
Sealing
enter air lines or fittings.
F a i l u r e to do so could result
Equipment Condition:
in equipment failure and/or
injury to personnel.
Reference
Condition Description
S e a l a n t compounds can burn
Page 2-28
Air System Drained
easily, can give off harmful
vapors, and are harmful to
skin and clothing. To avoid
injury or death, keep away
from open fire and use in
w e l l - v e n t i l a t e d area. If sealant
compound gets on skin or
clothing, wash immediately
w i t h soap and water.
|