![]() TM 9-2320-363-20-2 
FRONT GLADHANDS REPLACEMENT 
This task covers: 
a. Removal b. Cleaning/lnspection c. Installation 
INITIAL 
SETUP 
General Safety instructions: 
Tools and Special Equipment: 
Tool Kit, SC 5180-90-CL-N26 
WARNING 
Materials/Parts: 
 Make sure all air lines and 
fittings are clear of debris. 
Washer, Lock (2) 
Make  sure  excess  pipe 
P/N 23-10340-125 
Nut, Lock (2) 
sealant compound does not 
enter air lines or fittings. 
Appendix C, Item 8 
Compound, Pipe 
F a i l u r e to do so could result 
Sealing 
in equipment failure and/or 
i n j u r y to personnel. 
Equipment Condition: 
 Sealant compounds can burn 
Reference 
Condition Description 
easily, can give off harmful 
Air System Drained 
Page 2-28 
vapors, and are harmful to 
skin and clothing. To avoid 
injury or death, keep away 
from open fire and use in 
w e l l - v e n t i l a t e d area. If sealant 
compound gets on skin or 
clothing, wash immediately 
w i t h soap and water. 
 | 
| 
 
 Privacy Statement - Press Release - Copyright Information. - Contact Us  |