TM 9-2320-363-20-2
TRANSFER CASE SHIFT CONTROL CABLE REPLACEMENT (CONT)
INSTALLATION
1.
IN CAB, FEED TRANSFER CASE END OF CABLE (1) THROUGH FLOOR TO TRANSFER CASE.
2.
WITH TRANSFER CASE SELECTOR LEVER IN "N" POSITION, POSITION PIVOT PIN (2) ON BRACKET (3) AND
SECURE WITH RETAINING PIN (4).
3.
INSTALL SPACER (5), CABLE (1), CLAMP (6), TWO SCREWS (7), TWO NEW LOCK WASHERS (8), AND TWO
NUTS (9) TO BRACKET (10).
4.
SLIDE GROMMET (11) ON CABLE INTO CAB FLOOR.
4-384.14 Change 3
|