![]() TM 9-2320-363-20-2 
AUTOMATIC ETHER STARTING AID WIRING HARNESSES REPLACEMENT 
This task covers: 
a. Main Harness Replacement 
b. Jumper Harness Replacement 
INITIAL SETUP 
Applicable Configuration: 
Materials/Parts: 
All except M915A2 and M916A1 
Tie Wraps 
Appendix C, Item 36 
Tools and Special Equipment: 
Equipment Condition: 
Tool Kit, SC 5180-90-CL-N26 
Reference 
Condition Descripti on 
Page 2-29 
Batteries Disconnected 
MAIN HARNESS REPLACEMENT 
NOTE 
To ease in installation, note position of tie wraps. 
1. 
REMOVE TIE WRAPS ALONG MAIN HARNESS (1). 
2. 
DISCONNECT MAIN HARNESS (1) FROM ETHER FILTER HARNESS (2). 
3. 
DISCONNECT MAIN HA RNESS (1) FROM ETHER CONTROL RELAY HARNESS (3). 