![]() TM 9-2320-363-20-2 
CLEANING/INSPECTION 
Clean and inspect all parts in accordance with Chapter 2. 
INSTALLATION 
WARNING 
Diesel fuel is flammable. Do not work on fuel system in presence of sparks or 
open flame. To do so could result in serious injury to personnel. 
1. 
INSTALL TWO ELBOWS (14) IN STE/ICE DIFFERENTIAL SWITCH (2). 
2. 
INSTALL STE/ICE DIFFERENTIAL SWITCH (2), TWO WASHERS (13), TWO CAPSCREWS (12), TWO CLAMPS 
(11), TWO WASHERS (10), AND TWO NEW LOCK NUTS (9). 
3. 
INSTALL BRACKET (8), GROUND WIRE (7), TWO WASHERS (6), AND TWO CAPSCREWS (5). 
4. 
CONNECT ELECTRICAL CONNECTOR (3) TO WIRING HARNESS (4). 
5. 
CONNECT TWO FUEL LINES (1) TO STE/ICE DIFFERENTIAL SWITCH (2). 
NOTE 
Follow-on Maintenance: 
Connect batteries (page 2-29). 
 | 
| 
 