|
|
TM 9-2320-363-20-2
WARNING
Disconnect negative battery terminal before connecting or disconnecting any
electrical connectors. Failure to do so may result in electrical shock and injury to
personal.
NOTE
Tag all wires and cables prior to removal to aid in installation.
1.
REMOVE CAP (1), NUT (2), THREE WIRES (3), AND CABLE (4) FROM NEGATIVE BATTERY CABLE (5).
2.
REMOVE TWO CAPS (6), TWO NUTS (7), FOUR WIRES (8), AND THREE CABLES (9) FROM TWO POSITIVE
BATTERY CABLES (10).
3.
LOOSEN EIGHT NUTS (11) AND REMOVE NEGATIVE BATTERY CABLE (5) AND TWO POSITIVE BATTERY
CABLES (10).
CLEANING/INSPECTION
Clean and inspect all parts in accordance with Chapter 2.
INSTALLATION
1.
INSTALL TWO POSITIVE BATTERY CABLES (10) AND NEGATIVE BATTERY CABLE (5) AND TIGHTEN EIGHT
NUTS (11).
2.
INSTALL THREE CABLES (9), FOUR WIRES (8), TWO NUTS (7), AND TWO CAPS (6) ON TWO POSITIVE
BATTERY CABLES (10).
3.
INSTALL CABLE (4), THREE WIRES (3), NUT (2), AND CAP (1) ON NEGATIVE BATTERY CABLE (5).
NOTE
Follow-on Maintenance:
Install battery box cover (TM 9-2320-363-10).
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |