Page Title: INSTALLATION
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-363-20-2
3.
DISCONNECT WIRING HARNESS CONNECTOR
(5)  FROM  PARKING  BRAKE  PRESSURE
SWITCH (6).
WARNING
Always wear eye protection when
disconnecting air lines. Residual air
will be expelled. Failure to follow this
warning could cause serious eye
injury.
4.
REMOVE SWITCH (6) FROM CONNECTOR (7)
ON TEE (8).
INSTALLATION I
WARNING
Make sure all air lines and fittings are clear of debris. Make sure excess pipe
sealant compound does not enter air lines or fittings. Failure to do so could
result in equipment failure and/or injury to personnel.
Sealant compounds can burn easily, can give off harmful vapors, and are
harmful to skin and clothing. To avoid injury or death, keep away from open
fire and use in a well-ventilated area.  If sealant compound gets on skin or
clothing, wash immediately with soap and water.
Always wear eye protection when disconnecting air lines. Re sidual air will be
expelled.
1.
APPLY  SEALING  COMPOUND  TO  MALE
THREADS ON PARKING BRAKE PRESSURE
SWITCH (1).
2.
INSTALL SWITCH (1) IN CONNECTOR(2) ON
TEE (3).
3.
CONNECT WIRING HARNESS CONNECTOR (4)
TO PARKING BRAKE PRESSURE SWITCH (1).
Change 3 4-247.1