TM 9-2320-363-20-2
FIBER OPTIC LIGHT SOURCE REPLACEMENT (CONT)
CLEANING/INSPECTION
Clean and inspect all parts in accordance with Chapter 2.
INSTALLATION
CAUTION
D o not crimp fiber optic lines. Crimping could cause lines to break internally
r e s u l t i n g in instrument light failure.
1.
INSTALL FOUR FIBER OPTIC LINES (1) AND ENGAGE TWO LATCHES (2) ON REAR OF FIBER
..
OPTIC LIGHT SOURCE (3).
2.
INSTALL TIE STRAP (4).
INSTALL LIGHT SOCKET (5) IN FIBER OPTIC LIGHT SOURCE (3) AND TURN TO RIGHT.
3.
4.
INSTALL FIBER OPTIC LIGHT SOURCE (3), TORX SCREW (6), AND NEW SELF-LOCKING NUT (7).
NOTE
F o l l o w - o n Maintenance:
I n s t a l l center gage panel (M915A2) (page 4-174).
I n s t a l l center gage panel (M916A1) (page 4-176).
4-194
|