CENTER GAGE PANEL AND LAMPS AND INDICATOR LIGHTS REPLACEMENT
This task covers:
a. Removal
b. Cleaning/Inspection
c. Installation
INITIAL SETUP
Applicable Configuration:
Materials/Parts:
All except M915A2 and M916A1
Tags, Identification
Appendix C, It em 26
Tools and Special Equipment:
Equipment Condition:
Shop Equipment, SC 4910-95-CL-A72
Reference
Condition Description
Tool Kit, SC 5180-90-CL-N26
Page 2-29
Batteries Disconnected
REMOVAL
1.
REMOVE FOUR SCREWS (1) AND PULL PANEL (2) AWAY FROM DASHBOARD
NOTE
Tag connectors prior to removal to aid in installation.
2.
DISCONNECT TWO CONNECTORS (3) FROM CAB WIRING HARNESS CONNECTORS (4).
NOTE
M916A2 has two indicator lights. M917A1 and M917A1 w/MCS have five.
3.
DISCONNECT CAB WIRING HARNESS CONNECTORS (5) FROM INDICATOR LIGHTS (6) 4. DISCONNECT
CONNECTOR (7) FROM CAB WIRING HARNESS CONNECTOR (8) REMOVE PANEL (2).
5.
REMOVE TWO SCREWS (9), BRACKET (10), AND TACHOMETER (11) FROM PANEL (2). REMOVE LAMP (12)
6.
REMOVE TWO SCREWS (13), BRACKET (14), AND SPEEDOMETER (15) FROM PANEL (2). REMOVE LAMP
(16) FROM SPEEDOMETER.
7.
REMOVE INDICATOR LIGHTS (6) FROM PANEL (2).
CLEANING/INSPECTION
Clean and inspect all parts in accordance with Chapter 2.