TM 9-2320-363-20-2
INSTALLATION
WARNING
Make sure all air lines and fittings are clear of debris. Make sure excess pipe
sealant compound does not enter air lines or fittings. Failure to do so could result
in equipment failure and/or injury to personnel.
1.
COAT THREADS WITH PIPE SEALANT COMPOUND AND INSTALL TWO ELBOWS (2) IN GOVERNOR (5).
2.
INSTALL NEW GASKET (6), GOVERNOR (5), TWO NEW LOCK WASHERS (4), AND TWO SCREWS (3).
3.
CONNECT TWO LINES (1) TO TWO ELBOWS (2).
ADJUSTMENT
1.
REMOVE TOP COVER (1) FROM GOVERNOR (2).
2.
LOOSEN ADJUSTING SCREW LOCK NUT (3).
CAUTION
Be careful not to over adjust. Each 1/4 turn of adjusting screw raises or lowers
pressure setting approximately 4 psi (0.27 bar).
3.
TURN ADJUSTING SCREW (4) RIGHT TO LOWER PRESSURE; LEFT TO RAISE PRESSURE.
4.
WHEN PROPER ADJUSTMENT IS REACHED, TIGHTEN ADJUSTING SCREW LOCK NUT (3).
5.
INSTALL TOP COVER (1) ON GOVERNOR (2).
|