(6) Remove plug (9) from in put housing (4).
(7) Remove three plugs (10) from output
housing (5).
NOTE
Mark location of oil seal and plug
before removing to aid in installation.
(8) Remove plug (11), oil seal (12) and two
bearing cups (13) from input housing (4).
Discard oil seal.
(9) Remove plug (14), oil seal (15), and two
bearing cups (16) from output housing (5).
Discard oil seal.
(10) Remove two bearing cones (17) from
input shaft (6).
(11) Remove two bearing cones (18) and
shims (19) from output shaft (7).
(12) Position output shaft (7), gear (20) side
up, in suitable press.
CAUTION
Protect output shaft from striking
floor  while  pressing  from  gear.
Failure to comply may result in
damage to output shaft.
(13) Press output shaft (7) from gear (20).
(14) Remove key (21) from output shaft (7).
b. Cleaning/Inspection
WARNING
Dry cleaning solvent P-D-680 Is toxic and flammable. Wear protective goggles and
gloves and use solvent only in a well-ventilated area.  Avoid contact with skin,
eyes, and clothes, and don't breathe vapors.  Do not use near open flame or
excessive heat. The flash point Is 100-138 F (38-50 C). If you become dizzy while
using cleaning solvent, get fresh air immediately and get medical aid. If solvent
contacts eyes, wash eyes with water and get medical aid immediately.
(1) Clean metal parts in dry cleaning solvent.