TM 9-2320-360-34-2
23-2. TRANSFER CASE REPAIR (CONT)
(81)
Cut lockwire (127) holding two screws
(128).
(82)
Remove two screws (128) and upper shift
rod (39) from fork (129).
(83)
Remove spacer (59) and eight spring
disks (60).
(84)
Cut lockwire (130) holding screw (131).
(85)
Remove screw (131) from fork (132).
(86)
Slide shift rod (133) from fork (132).
(87)
Remove stud (134) from lower shift rod
(133).
b.
Cleaning/inspection
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and
clothes, and don't breathe vapors. DO NOT use near open flame or excessive heat.
o
o
The flash point is 100-138 F (38-54 C). If you become dizzy while using cleaning
solvent, get fresh air immediately and medical aid. If contact with eyes is made,
wash your eyes with water and get medical aid immediately.
(1)
Clean all metal parts with dry cleaning
solvent.
(2)
Clean all sealing surfaces.
23-14
|