TM 9-2320-360-34-2
c. Cleaning/Inspection
WARNING
Dry cleaning solvent P-D-680 Is toxic and flammable. Wear protective goggles and
gloves and use only In a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and don't breathe vapors. DO NOT use near open flame or excessive heat.
The flash point Is 100-138 F (38-59 C). If you become dizzy while using cleaning
solvent, get fresh air immediately and medical aid. If contact with eyes Is made,
wash your eyes with water and get medical aid Immediately.
(1) Clean metal parts with dry cleaning
solvent and inspect for damage. Replace
damaged parts.
(2) Inspect all parts for burrs, scratches, and
pitting. Remove defects.
(3) Inspect all parts for missing or broken
splines or teeth. Replace all damaged
parts.
NOTE
Do step (4) for piston release springs
coded light blue. Do step (5) for
piston release springs coded light
green.
(4) Measure piston release spring lengths
using spring tester (1). Replace piston
release springs if any three of each set do
not meet the following load-height
requirements:
(a) Length without load must be at least
1.31 in. (33.3 mm).
(b) Length under load must be at least
0.90 in. (22.9 mm) with a load of
26-28 lb (11.8-12.7 kg).
(5) Measure piston release spring lengths
using spring tester (1). Replace piston
release springs if any three of each set do
not meet the following load-height
requirements:
(a) Length without load must be at least
1.29 in. (32.7 mm).
(b) Length under load must be at least
0.82 in. (20.8 mm) with a load of
4.3-5.7 lb (2-2.6 kg).
22-101
|